Broadcom published VMware Security Advisory VMSA-2026-0011 on 24 November 2026, rated Critical, with fixes for 23 vulnerabilities in VMware ESX, vCenter, Workstation, Fusion, VMware Tools and Avi Load Balancer. Four are rated Critical. CVE-2026-123903 is an authentication bypass in the vCenter Directory Service, scored 9.8 out of 10 on version 3.1 of the Common Vulnerability Scoring System (CVSS), that lets someone with network access to vCenter get in without valid credentials. CVE-2026-123910 and CVE-2026-123911, both scored 9.8, are memory flaws in the ESX I/O filter service that let someone with network access to the ESX host run code on the host itself, without needing access to a virtual machine. CVE-2026-123912 is a flaw in the virtual USB controller, scored 9.3 on Workstation and Fusion and 8.5 on ESX, where it stays contained inside the virtual machine process sandbox. Broadcom lists no workaround. Its advisory does not say any of these flaws are being exploited. Broadcom notes that CVE-2026-123903 is a new and separate flaw from CVE-2026-123890, the vCenter flaw that was exploited as a zero-day and patched on 19 November in VMSA-2026-0009.
In many plants, water and wastewater facilities, pipelines and utilities, the supervisory control and data acquisition (SCADA) servers, historians, operator workstations, engineering workstations and domain controllers all run as virtual machines on one small VMware cluster. Control system vendors often ship and support that cluster as part of the system, and it can stay on the same version for years because nobody wants to touch it. Whoever controls vCenter or an ESX host controls every one of those servers at once. They can power them off, copy them, or change them. Two of these flaws need only network access to the ESX host, and one needs only network access to vCenter. This comes one week after a vCenter flaw was exploited as a zero-day, and attackers often study one patch to find the next.
The VMware hosts usually sit in the control room server rack or a Level 3 operations network, running the SCADA, historian and human machine interface (HMI) servers. vCenter, the management console for those hosts, is often on the same network, and sometimes reachable from the business network, a vendor remote access tool or the plant demilitarized zone (DMZ). Engineers and integrators also run VMware Workstation on laptops to keep older engineering software in virtual machines.
Red Tiger can help you find the virtualization layer under your control system and see who can reach it. During our onsite facility assessments, our team walks the system from the perimeter through the demilitarized zone (DMZ) and control room down to the field devices, including the server racks, virtualization hosts and management networks that the SCADA and historian servers run on. We can then help remediate and harden what we find, and install a firewall and sensor at the site, connect them to the Red Tiger 24x7 security operations center (SOC), and monitor the site for ongoing detection and response, with regular metrics and reports. Our team has completed more than 500 assessments and trained more than 4,500 people.
We are here to help, so check out our resources online at www.redtigersecurity.com and book a follow-up call with our team if you have any questions: https://calendly.com/jonathanpollet/30min
Source: Broadcom, VMware Security Advisory VMSA-2026-0011, 24 November 2026: https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/39626
Check out our resources and book a follow-up call with our team.