November 25, 2026
← All advisories

CISA Adds Exploited Juniper Session Smart Conductor and Router Flaw to KEV

Red Tiger Security infographic: Exploited: Juniper Session Smart flaw CVE-2026-103406. A command injection flaw gives an attacker with no password root on Session Smart Conductor, which manages Juniper's SD-WAN routers. Timeline: 28 October 2026 Juniper bulletin with the fix, no attacks reported; 24 November Juniper reports malicious exploitation; 25 November CISA adds it to the Known Exploited Vulnerabilities catalog; 28 November federal due date. Callouts: severity 9.8 critical, root access, no workaround, fixed in Conductor 7.0.5, 7.1.7, 7.2.3 or later. SD-WAN routers link remote and plant sites to the control center and often sit in the path to the plant network. Four steps: find every Conductor and router, upgrade, check for compromise, and put a firewall between each site router and the plant network.

On 25 November 2026, the Cybersecurity and Infrastructure Security Agency (CISA) added CVE-2026-103406 to its Known Exploited Vulnerabilities (KEV) catalog, the agency's list of flaws that attackers are using in the real world. The flaw affects Juniper Session Smart Conductor, and CISA's entry also names Session Smart Router. CISA lists the vendor as Hewlett Packard Enterprise (HPE), which now owns Juniper Networks. Juniper rates the flaw 9.8 out of 10, which is critical, and says no workaround exists.

What it is

CVE-2026-103406 is an operating system (OS) command injection flaw. That means an attacker can slip their own commands into a piece of data that the system later hands to its operating system, and the system runs those commands as if they were its own. In this case, Juniper says the flaw is in the AutomatedProvisioner part of Session Smart Conductor and is triggered during key management. An attacker who sends a specially crafted "salt minion ID," the name a managed device uses to identify itself to the Salt configuration management software, can run any command they want as root, the all-powerful administrator account. Juniper's record says the attacker does not need a password.

Session Smart Router is a software-defined wide area network (SD-WAN) router. SD-WAN routers connect many distributed sites over internet and private links and are managed centrally. Session Smart Conductor is that central management system. It holds the configuration for every router it manages and pushes changes out to them.

What is new

Juniper fixed this flaw on 28 October 2026 in an out-of-cycle security bulletin covering several vulnerabilities in Session Smart Router and Session Smart Conductor that Juniper's own team had found. At that time, no attacks had been reported. On 24 November, Juniper updated its record for this flaw to say that "at least one instance of malicious exploitation has been reported to the Juniper SIRT," its security incident response team. CISA added it to the KEV catalog the next day and gave federal civilian agencies until 28 November 2026 to apply the fix, only three days. CISA also marked the entry as requiring forensic triage, which means agencies must look for signs that they were already compromised, not just patch. CISA lists ransomware use as unknown. Neither Juniper nor CISA has said who is behind the attacks or how many systems were hit.

Fixed releases. Juniper's record for CVE-2026-103406 lists Session Smart Conductor 7.0.5, 7.1.7 and 7.2.3, and all later releases, as fixed. Versions before 7.0.5, 7.1.0 up to 7.1.7, and 7.2.0 up to 7.2.3 are affected. The Canadian Centre for Cyber Security's summary of the same bulletin lists Session Smart Router releases before 7.0.5, 7.1.7 and 7.2.3 as affected as well. Use the fixed releases listed in the Juniper bulletin for each product.

What this means for operational technology owners

SD-WAN routers are how many organizations connect distributed sites, such as remote facilities, pump and lift stations, field and plant sites, and branch offices, back to a control center or data center. The router at each site often sits directly in the path to the plant network, and the Conductor can change the configuration of every one of those routers at once. An attacker with root on the Conductor or on a router can reroute or open traffic, read the keys and passwords stored in the configuration, and use the router as a quiet foothold next to the control system. Juniper Session Smart is not an industrial control system (ICS) product, but in many networks it is the road into one.

Where this shows up, plant floor to cloud

Session Smart Routers at remote and field sites, at the edge of plant networks, and at branch offices. Session Smart Conductor in the corporate data center, at a managed service provider, or running as a virtual machine in a cloud environment. The links between them over the internet, cellular and private circuits. The Conductor is the part named in Juniper's record, and because it manages every router, it is the first place to look.

What Red Tiger recommends

  1. Find every Session Smart Conductor and Session Smart Router you own or that a service provider runs for you, and record the software version of each. Check whether the Conductor can be reached from the internet. Juniper says there is no workaround, so limiting who can reach the Conductor lowers the risk but does not fix the flaw.
  2. Upgrade the Conductor to 7.0.5, 7.1.7, 7.2.3 or a later release now, and then upgrade the routers to the fixed releases in the Juniper bulletin. Plan router upgrades with operations, because the router carries the site's connection, and make sure someone can reach the site if the link does not come back.
  3. Treat any Conductor or router that ran an affected version as possibly compromised. Review it for devices registered that nobody recognizes, configuration changes nobody made, new administrator accounts and unexpected outbound connections, and work with Juniper support. If anything looks wrong, rebuild from a known-good configuration and reset the keys and passwords stored on the system.
  4. Make sure the SD-WAN router is not the only thing between the wide area network and the control system. Put a firewall between each site's router and the plant network, and allow only the traffic the site actually needs.

Red Tiger can help. During our plant-safe onsite assessments, our team walks the system from the perimeter through the demilitarized zone (DMZ, the buffer network between business and control systems) and control room down to the field devices, including wide area network routers, remote site connections and vendor remote access paths. We can then help remediate and harden what we find, and install a firewall and sensor at the site, connect them to the Red Tiger 24x7 security operations center (SOC), and monitor the site for ongoing detection and response, with regular metrics and reports. Our team has completed more than 500 assessments and trained more than 4,500 people.

We are here to help, so check out our resources online at www.redtigersecurity.com and book a follow-up call with our team if you have any questions: https://calendly.com/jonathanpollet/30min

Source: CISA Known Exploited Vulnerabilities catalog, CVE-2026-103406, added 25 November 2026: https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-103406

Vendor bulletin: Juniper Networks 2026-10 On-Demand Security Bulletin, Session Smart Router and Session Smart Conductor: https://supportportal.juniper.net/s/article/2026-10-On-Demand-Security-Bulletin-Session-Smart-Router-and-Session-Smart-Conductor-Multiple-internally-discovered-vulnerabilities-resolved

Vulnerability record: National Vulnerability Database (NVD), CVE-2026-103406: https://nvd.nist.gov/vuln/detail/CVE-2026-103406

← All advisories

Cite this advisory: Red Tiger Security, "CISA Adds Exploited Juniper Session Smart Conductor and Router Flaw to KEV", November 25, 2026, https://www.redtigersecurity.com/advisory/juniper-session-smart-router-kev-cve-2026-103406

Read the original source →

We are here to help.

Check out our resources and book a follow-up call with our team.

+1.877.387.7733