The Cybersecurity and Infrastructure Security Agency (CISA) published advisory ICSA-26-328-03 on 24 November 2026 for the Danfoss AK-SM 8xxA series, the refrigeration system managers used in supermarkets, cold storage warehouses and food distribution. It assigns a Common Vulnerabilities and Exposures (CVE) identifier, CVE-2026-129713, to a stack-based buffer overflow in a web request handler on the controller that does not require a login. CISA scores it 9.8 out of 10 on version 3.1 of the Common Vulnerability Scoring System (CVSS) and 9.3 on version 4.0. All versions up to and including 5.4.0 are affected, and there is still no fix. CISA credits Carlo Meijer of Midnight Blue with reporting the flaw. This is a follow-up to our 12 November advisory on the Danfoss AK-SM800A: https://www.redtigersecurity.com/advisory/danfoss-ak-sm800a-unpatched-zero-days
According to CISA, specially crafted requests sent to the controller's web interface can corrupt memory, restart the web server, and could potentially let an attacker run their own code with the web server's privileges. No password is needed. CISA says no known public exploitation specifically targeting this vulnerability has been reported to it at this time.
This advisory lands in the middle of an active campaign against refrigeration controllers. Since October, attackers have reached internet-exposed refrigeration controllers from Danfoss, Copeland and Dixell in France and across Europe, causing unwanted defrost cycles and lost stock. France has attributed the October attack to a cyber unit of Iran's Islamic Revolutionary Guard Corps (IRGC), and United States agencies issued a joint fact sheet on hardening refrigeration and cold chain monitoring systems on 5 November. Those attacks have not been tied to this CVE, but they show that attackers are already looking for these controllers on the internet, and a login-free flaw in the web interface with no patch is exactly what owners do not want exposed.
A refrigeration system manager usually sits in a back room or plant room and controls case temperatures, compressor racks and defrost schedules for a whole store or warehouse. Above it, the refrigeration service contractor often reaches it remotely through a cellular modem or a direct internet address, and data may flow to a monitoring service in the cloud. That remote path is the part attackers have been using. The same pattern exists in food and beverage plants, pharmaceutical cold chain, and any commercial building where a contractor manages equipment from outside.
Red Tiger has completed more than 500 operational technology (OT) security assessments and trained more than 4,500 people, and contractor-managed building and process equipment is one of the most common blind spots we find. During our onsite facility assessments, our team walks the system from the perimeter through the demilitarized zone (DMZ) and control room down to the field devices, including contractor modems and remote access paths. We can then help remediate what we find, and install a firewall and sensor at the site, connect them to the Red Tiger 24x7 security operations center (SOC), and monitor the site for ongoing detection and response, with regular metrics and reports.
We are here to help, so check out our resources online at www.redtigersecurity.com and book a follow-up call with our team if you have any questions: https://calendly.com/jonathanpollet/30min
Source: CISA, ICS Advisory ICSA-26-328-03, Danfoss AK-SM 8xxA Series, 24 November 2026: https://www.cisa.gov/news-events/ics-advisories/icsa-26-328-03
Check out our resources and book a follow-up call with our team.